Configuring Communication Settings
40
TPI-PRO/DVI (Total Presentation Interface)
The basic steps involved with configuring the TPI-PRO/DVI’s communications settings include:
1.
Assign a Device Number to the TPI-PRO/DVI (see page 40).
2.
Set the Serial Port Baud Rate (see page 41).
3.
Configure the Master Connection Settings (see page 42).
Assigning a Device Number to the TPI-PRO/DVI
1.
Press the front panel SETUP pushbutton to open the
Setup
2.
Press the
Protected Setup
button to open the
Protected Setup
page. This page is password-protected:
a.
Use the on-screen keypad to enter the default password -
1988.
b.
Press
Done
to close the keypad (FIG. 36).
3.
Enter a
Device Number
value for the TPI-PRO/DVI (FIG. 36):
a.
Press the red
Device ID
field to open the keypad.
b.
Enter a Device Number value for the TPI-PRO/DVI
.
c.
Press
Done
to assign the device number close the keypad.
The default value is
10001
Range =
1 - 32000
When using multiple TPI-PRO-DVIs within a NetLinx System, assign unique Device Number
values to each TPI-PRO/DVI.
FIG. 35
Setup page - Protected Setup button
Press to access the
Protected Setup
page
(password-protected)
Clearing Password #5 from the initial Password Setup page, removes the need for
you to enter the default password before accessing the Protected Setup page.
Summary of Contents for TPI-PRO-4
Page 14: ...xii TPI PRO Total Presentation Interface Table of Contents ...
Page 76: ...TPI PRO DVI Configuration Pages 70 TPI PRO DVI Total Presentation Interface ...
Page 172: ...Terminal Telnet Commands 166 TPI PRO DVI Total Presentation Interface ...
Page 180: ...Upgrading Firmware 174 TPI PRO DVI Total Presentation Interface ...
Page 208: ...Supported Input and Output Modes 202 TPI PRO DVI Total Presentation Interface ...
Page 214: ...Appendix 208 TPI PRO DVI Total Presentation Interface ...
Page 217: ...Troubleshooting 203 TPI PRO Total Presentation Interface ...