Notes: Units DCF092TX-21HVVV DCF095TX-21HVVW DCF097TX-21HVWW
SEPR
1,3,5
6.74
6.66
6.56
SEPR Tier
Tier 2 (2021)
Tier 2 (2021)
Tier 2 (2021)
Annual Electricity Consumption
kWh/a
919429
960763
1005378
Rated Refrigerant Capacity
P
A
1,3,5
kW
836.3
863.5
890.7
Rated Power Input D
A
kW
279.7
295.7
310.3
Rated EER
DC,A
2.99
2.92
2.87
Declared Refrigerant Capacity P
B
1,3,5
kW
844.9 / 745.2
868.7 / 769.0
900.1 / 792.7
Declared Power Input D
B
kW
203.3 / 175.9
211.1 / 183.7
223.6 / 191.5
Declared EER
DC,B
4.16 / 4.24
4.12 / 4.19
4.03 / 4.14
Declared Refrigerant Capacity P
C
1,3,5
kW
811.0 / 700.3
835.8 / 725.1
860.6 / 749.9
Declared Power Input D
C
kW
147.2 / 124.0
153.6 / 130.4
160.1 / 136.9
Declared EER
DC,C
5.51 / 5.65
5.44 / 5.56
5.37 / 5.48
Declared Refrigerant Capacity P
D
1,3,5
kW
664.3 / 605.8
685.7 / 619.4
707.1 / 646.7
Declared Power Input D
D
kW
65.1 / 90.9
67.8 / 93.4
70.9 / 98.5
Declared EER
DC,D
10.20 / 6.67
10.12 / 6.63
9.98 / 6.57
SSCEE
2,3,5
%
169.2
167.0
164.3
SSCEE Tier
6
Tier 1 (2018)
Tier 1 (2018)
Tier 1 (2018)
Rated Cooling Capacity P
rated,c
2,4,5
841
868.6
896.2
Declared Cooling Capacity 35°C Pdc 2,3,5
kW
836.3
863.5
890.7
Declared EER
d
35°C
2.99
2.92
2.87
Declared Cooling Capacity 30°C Pdc 2,3,5
kW
844.9 / 745.2
868.7 / 769.0
900.1 / 792.7
Declared EER
d
30°C
4.16 / 4.24
4.12 / 4.19
4.03 / 4.14
Declared Cooling Capacity 25°C Pdc 2,3,5
kW
811.0 / 700.3
835.8 / 725.1
860.6 / 749.9
Declared EER
d
25°C
5.51 / 5.65
5.44 / 5.56
5.37 / 5.48
Declared Cooling Capacity 20°C Pdc 2,3,5
kW
664.3 / 605.8
685.7 / 619.4
707.1 / 646.7
Declared EER
d
20°C
10.20 / 6.67
10.12 / 6.63
9.98 / 6.57
Sound Power Level LWA
dB(A)
Air flow rate
m³/h
302214
302214
302214
Off mode P
OFF
kW
0.169
0.169
0.169
Thermostat-off mode P
TO
kW
5.531
5.981
6.453
Standby Mode P
SB
kW
0.383
0.383
0.383
Crankcase heater mode P
CK
kW
0.000
0.000
0.000
Technical Data
Ecodesign
DCF092TX-21HVVV, DCF095TX-21HVVW, DCF097TX-21HVWW
(1) Nominal conditions as stated in EU 2016/2281 Table 22.
(2) Nominal conditions as stated in EU 2016/2281 Table 21
(3) Performance data (Nett) is supplied in accordance with EN14511-1:2013.
(4) Performance data (Gross) is supplied excluding absorbed pump power as per EN14511-1:2013.
(5) All performance data based upon standard waterside configuration.
(6) Please contact Airedale regarding Non Compliant selections
Chillers
Introduction
DeltaChill™ Air Cooled and FreeCool
294
Chiller Technical Manual 7267818 V1.13.0_01_2018