Removing step 2 - Cable and hose retainer (wrist) & hose reinforcement funnel
Use this procedure to remove the cable and hose retainer (wrist) and the hose
reinforcement funnel.
Note
Let the cable package stay fitted in the ball joint housing on the upper arm tube
during this procedure.
Note
Action
xx1200000102
Remove the
clamp jaw
closest to the wrist.
1
xx1200000159
Remove the
hose clamp
securing the cable
and hose retainer.
2
xx1200000103
Remove the
cable and hose retainer
.
3
Continues on next page
282
Product manual - DressPack/SpotPack IRB 6640
3HAC028638-001 Revision: K
© Copyright 2007-2018 ABB. All rights reserved.
4 Repair
4.2.12 Replacing the protection hose - IRBDP SW6 UI and MH6 UI - Upper arm
Continued