2.6 Water & Air unit
2.6.1 Installation of Water and air unit
Location of Water and air unit, type S
The Water and air unit type S is located as shown in the figure below. The figure
shows the Water and air unit fitted on IRB 6620, but the principle is the same the
other models.
xx0600003205
Water and air unit, type S
A
Attachment screws M6x8 quality 8.8-A2F, Water in and water return unit (6 pcs)
B
Attachment plate
C
Attachment screws M6x8 quality 8.8-A2F, Water and air unit (4 pcs)
D
Tightening torque, brass couplings 1/2": 31
Nm
CAUTION
Do not tighten the brass couplings for water
and air with excessive force.
Tightening torque, brass couplings 3/8": 17
Nm
Continues on next page
Product manual - DressPack/SpotPack IRB 6640
175
3HAC028638-001 Revision: K
© Copyright 2007-2018 ABB. All rights reserved.
2 Installation
2.6.1 Installation of Water and air unit
Summary of Contents for DressPack IRB 6640
Page 1: ...ROBOTICS Product manual DressPack SpotPack IRB 6640 ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 44: ...This page is intentionally left blank ...
Page 194: ...This page is intentionally left blank ...
Page 220: ...This page is intentionally left blank ...
Page 324: ...This page is intentionally left blank ...
Page 338: ...This page is intentionally left blank ...
Page 364: ...This page is intentionally left blank ...
Page 366: ...This page is intentionally left blank ...
Page 369: ......