2.6.2 Return water flow control
Overview
The mechanical flow control valve is pre-set at delivery at 8 liter/min (maximum
flow).
Settings
The procedure below details how to set the mechanical flow control valve.
Note
Action
Open the solenoid valve on the water inlet.
1
Water flow is indicated on the scale of the Flow
control valve.
2
The red adjusting knob is placed
on the back of the Water and Air
unit.
Adjust water flow by using the red adjusting knob
on the scale of the Flow control valve to the required
set flow.
3
Product manual - DressPack/SpotPack IRB 6640
187
3HAC028638-001 Revision: K
© Copyright 2007-2018 ABB. All rights reserved.
2 Installation
2.6.2 Return water flow control