Maintenance procedure
Note
Action
DANGER
Before any work inside the cabinet, please
observe the safety information in the sec-
tion
DANGER - Make sure that the main
power has been switched off
in the product
manual for the IRC5 controller.
1
xx0500002240
Remove the attachment screws.
2
•
A: Attachment screw M5x9 Fastite
(3 pcs)
•
B: Fan casing
•
C: Cooling fins
Disconnect the fan connector.
3
Remove the fan casing.
4
Clean the cooling fins with a vacuum
cleaner.
5
Refit the fan connector and fan casing.
6
Product manual - DressPack/SpotPack IRB 6640
219
3HAC028638-001 Revision: K
© Copyright 2007-2018 ABB. All rights reserved.
3 Maintenance
3.4.4 Cleaning the Weld timer cooling fins