Note
Action
Tightening torque, brass couplings 1/2":
31Nm
Back:
Refit the cables and hoses on the connec-
tion plate.
CAUTION
Do not tighten the brass couplings for
water and air with excessive force.
15
Tightening torque, brass couplings 3/8":
17Nm
Recheck all cables and hoses for straining
or twisting. Reroute if required!
xx0700000429
Parts:
•
A: R3.WELD
•
B: Connection plate
•
C: Lower arm plate
•
D: Lower gripping clamp (lower arm
plate)
•
E: R3.PROC 1-5
•
F: R3.CP/CS/CBUS
Back:
16
Snap the cable package back into the
upper gripping clamp on the lower arm
plate and gripping clamp on the upper
arm.
Back:
17
Reconnect the R3.WELD connector,
R3.CP/CS/CBUS connector and
R3.PROC1-5 on the connection plate.
264
Product manual - DressPack/SpotPack IRB 6640
3HAC028638-001 Revision: K
© Copyright 2007-2018 ABB. All rights reserved.
4 Repair
4.2.8 Replacement process cable package IRBDP SW4 UI (IRB66X0ID)
Continued