![ABB DressPack IRB 6640 Product Manual Download Page 251](http://html.mh-extra.com/html/abb/dresspack-irb-6640/dresspack-irb-6640_product-manual_5004251.webp)
Note
Action
xx0500001944
Front:
Loosen the
screws
, M6x60 (4 pcs) that
are locking the process cable package
in position at the
holder front
.
This is done in order to release the
tension in the process cable package.
Note
Do not remove the screws completely
at this point!
8
Parts:
•
A: Holder front
•
B: Hex socket head cap screw M6x60
xx0500002502
Back and front together:
Front:
Pull out the cables and hoses a little
from their holes, one by one.
Back:
Push the cables and hoses forward,
one by one.
9
This procedure is done in order to make it
possible to remove the covers from the hoses
and cables in the turning disk unit.
Due to long operation the cable package may
be jammed.
Depending on the cable package shall be re-
used or not, follow the appropriate advice
below:
•
If the cable package shall be
reused
do not be afraid to pull harder to get
the cables out. Still be careful not to
damage it!
•
If the cable package is
scrap
pull the
cable package out far enough to make
it possible to cut off cables and hoses.
Continues on next page
Product manual - DressPack/SpotPack IRB 6640
251
3HAC028638-001 Revision: K
© Copyright 2007-2018 ABB. All rights reserved.
4 Repair
4.2.8 Replacement process cable package IRBDP SW4 UI (IRB66X0ID)
Continued
Summary of Contents for DressPack IRB 6640
Page 1: ...ROBOTICS Product manual DressPack SpotPack IRB 6640 ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 44: ...This page is intentionally left blank ...
Page 194: ...This page is intentionally left blank ...
Page 220: ...This page is intentionally left blank ...
Page 324: ...This page is intentionally left blank ...
Page 338: ...This page is intentionally left blank ...
Page 364: ...This page is intentionally left blank ...
Page 366: ...This page is intentionally left blank ...
Page 369: ......