222
YASKAWA
TOEPYAIHV6002A HV600 Drive Programming
2.4
C: Tuning
C parameters
adjust drive operation, including:
•
Acceleration Time
•
Deceleration Time
•
Slip Compensation
•
Torque Compensation
•
Carrier Frequency
◆
C1: Accel & Decel Time
You can set two different acceleration and deceleration time pairs in the drive. When you activate and deactivate
H1-
xx = 7, 16 [MFDI Function Selection = Accel/Decel Time Selection 1, Motor 2 Selection]
, you can switch
acceleration and deceleration times during run.
Acceleration time parameters always set the time to accelerate from 0 Hz to
E1-04 [Maximum Output Frequency]
.
Deceleration time parameters always set the time to decelerate from
E1-04
to 0 Hz.
C1-01 [Acceleration Time 1]
and
C1-02 [Deceleration Time 1]
are the default active accel/decel settings.
Parameter
Range
C1-01 [Acceleration Time 1]
0.1 to 6000.0 s
C1-02 [Deceleration Time 1]
C1-03 [Acceleration Time 2]
C1-04 [Deceleration Time 2]
C1-05 [Acceleration Time 3]
C1-06 [Deceleration Time 3]
C1-07 [Acceleration Time 4]
C1-08 [Deceleration Time 4]
■
Use MFDIs to Switch Acceleration Times
shows the different acceleration and deceleration times.
Table 2.31 Accel/Decel Times and Active Parameters
H1-xx = 7
[Accel/Decel Time Selection 1]
Active Parameter
Acceleration Time
Deceleration Time
OFF
C1-01 [Acceleration Time 1]
C1-02 [Deceleration Time 1]
ON
C1-03 [Acceleration Time 2]
C1-04 [Deceleration Time 2]
shows an operation example to change acceleration and deceleration times. It is necessary to set
b1-03 =
0 [Stopping Method Selection = Ramp to Stop]
for this example.
Содержание HV600
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 16: ...i 3 Warranty Information 16 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 158: ...1 22 Defaults by o2 04 Drive Model kVA Selection 158 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 506: ...2 14 Y Application Features 506 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...