256
YASKAWA
TOEPYAIHV6002A HV600 Drive Programming
■
E3-06: Motor 2 Base Frequency
No.
(Hex.)
Name
Description
Default
(Range)
E3-06
(031C)
Motor 2 Base Frequency
Sets the base frequency for the motor 2 V/f pattern.
Determined by E3-01
(0.0 - E3-04)
■
E3-07: Motor 2 Mid Point A Frequency
No.
(Hex.)
Name
Description
Default
(Range)
E3-07
(031D)
Motor 2 Mid Point A
Frequency
Sets a middle output frequency for the motor 2 V/f pattern.
Determined by E3-01
(0.0 - E3-04)
■
E3-08: Motor 2 Mid Point A Voltage
No.
(Hex.)
Name
Description
Default
(Range)
E3-08
(031E)
Motor 2 Mid Point A Voltage
Sets a middle output voltage for the motor 2 V/f pattern.
Determined by E3-01
(208 V Class: 0.0 - 255.0 V,
480 V Class: 0.0 - 510.0 V)
■
E3-09: Motor 2 Minimum Output Frequency
No.
(Hex.)
Name
Description
Default
(Range)
E3-09
(031F)
Motor 2 Minimum Output
Frequency
Sets the minimum output frequency for the motor 2 V/f pattern.
Determined by E3-01
(0.0 - E3-04)
■
E3-10: Motor 2 Minimum Output Voltage
No.
(Hex.)
Name
Description
Default
(Range)
E3-10
(0320)
Motor 2 Minimum Output
Voltage
Sets the minimum output voltage for the motor 2 V/f pattern.
Determined by E3-01
(208 V Class: 0.0 - 255.0 V,
480 V Class
■
E3-11: Motor 2 Mid Point B Frequency
No.
(Hex.)
Name
Description
Default
(Range)
E3-11
(0345)
Expert
Motor 2 Mid Point B
Frequency
Sets a middle output frequency for the motor 2 V/f pattern. Set this parameter to adjust the V/f
pattern for the constant output range. Usually it is not necessary to change this parameter.
0.0 Hz
(0.0 - E3-04)
Note:
•
Set this parameter to
0.0
to disable the function.
•
When you initialize the drive, this parameter is reset to the default value.
■
E3-12: Motor 2 Mid Point B Voltage
No.
(Hex.)
Name
Description
Default
(Range)
E3-12
(0346)
Expert
Motor 2 Mid Point B Voltage
Sets a middle output voltage for the motor 2 V/f pattern. Set this parameter to adjust the V/f pattern
for the constant output range. Usually it is not necessary to change this parameter.
0.0 V
(208 V Class: 0.0 - 255.0 V,
480 V Class: 0.0 - 510.0 V)
Note:
•
Set this parameter to 0.0 to disable the function.
•
When you initialize the drive, this parameter is reset to the default value.
•
The setting value changes automatically when you do Auto-Tuning (rotational and stationary 1 or 2).
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
Содержание HV600
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 16: ...i 3 Warranty Information 16 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 158: ...1 22 Defaults by o2 04 Drive Model kVA Selection 158 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 506: ...2 14 Y Application Features 506 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...