2.2 A: Initialization Parameters
YASKAWA
TOEPYAIHV6002A HV600 Drive Programming
175
User Parameter No.
Parameter No. Saved
Name
A2-05
b5-03
Integral Time (I)
A2-06
b5-08
PID Primary Delay Time Constant
A2-07
b5-09
PID Output Level Selection
A2-08
C1-01
Acceleration Time 1
A2-09
d2-03
Analog Frequency Ref Lower Limit
A2-10
H1-07
Terminal S7 Function Selection
A2-11
H3-01
Terminal A1 Signal Level Select
A2-12
H3-02
Terminal A1 Function Selection
A2-13
H3-10
Terminal A2 Function Selection
A2-14
L5-01
Number of Auto-Restart Attempts
A2-15
o1-24
Custom Monitor 1
A2-16
o1-25
Custom Monitor 2
A2-17
o1-26
Custom Monitor 3
A2-18
Y1-04
Sleep Wake-up Level
A2-19
Y1-05
Sleep Wake-up Level Delay Time
A2-20
Y1-08
Low Feedback Level
A2-21
Y1-09
Low Feedback Lvl Fault Dly Time
A2-22
Y2-01
Sleep Level Type
A2-23
Y2-02
Sleep Level
A2-24
Y2-03
Sleep Delay Time
A2-25
Y2-04
Sleep Activation Level
■
A1-07: DriveWorksEZ Function Selection
No.
(Hex.)
Name
Description
Default
(Range)
A1-07
(0128)
DriveWorksEZ Function
Selection
Sets the drive to operate with DriveWorksEZ.
0
(0 - 2)
DriveWorksEZ is a simple visual programming tool that lets you connect function blocks to customize the drive and
add PLC functions.
Note:
•
DriveWorksEZ will overwrite drive settings when it uses MFDI/MFDO and MFAI/MFAO. When you use DriveWorksEZ to make changes
to the drive, the changes will stay after you disable DriveWorksEZ.
•
For more information about DriveWorksEZ, contact Yaskawa or your nearest sales representative.
0 : DWEZ Disabled
1 : DWEZ Enabled
2 : Enabled/Disabled wDigital Input
Set
H1-xx = 9F [MFDI Function Select = DWEZ Disable]
. Deactivate the digital input to enable programs made with
DriveWorksEZ and activate the terminal to disable the programs.
■
A1-11: Firmware Update Lock
No.
(Hex.)
Name
Description
Default
(Range)
A1-11
(111D)
Expert
Firmware Update Lock
Protects the drive firmware. When you enable the protection, you cannot update the drive firmware.
0
(0, 1)
0 : Disabled
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
Содержание HV600
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 16: ...i 3 Warranty Information 16 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 158: ...1 22 Defaults by o2 04 Drive Model kVA Selection 158 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 506: ...2 14 Y Application Features 506 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...