Bit
Name
Reset
Access Description
0
NONE
No interrupt is generated
1
LEVEL
Set interrupt flag if the sensor triggers.
2
POSEDGE
Set interrupt flag on positive edge of the sensor state
3
NEGEDGE
Set interrupt flag on negative edge of the sensor state
4
BOTHEDGES
Set interrupt flag on both edges of the sensor state
13:12
SAMPLE
0xX
RW
Select Sample Mode
Select measurement to be used for evaluation
Value
Mode
Description
0
ACMPCOUNT
Counter output will be used in evaluation
1
ACMP
ACMP output will be used in evaluation
2
ADC
ADC output will be used in evaluation
3
ADCDIFF
Differential ADC output will be used in evaluation
11:0
THRES
0xXXX
RW
ACMP Threshold or VDAC Data
Set threshold used for ACMP, or data used in VDAC conversion.
Reference Manual
LESENSE - Low Energy Sensor Interface
silabs.com