Bit
Name
Reset
Access Description
5
PRSCH5
PRS Channel 5 selected as input
6
PRSCH6
PRS Channel 6 selected as input
7
PRSCH7
PRS Channel 7 selected as input
8
PRSCH8
PRS Channel 8 selected as input
9
PRSCH9
PRS Channel 9 selected as input
10
PRSCH10
PRS Channel 10 selected as input
11
PRSCH11
PRS Channel 11 selected as input
15:9
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
8
CONT
0
RW
Continuous Calibration
Set this bit to enable continuous calibration
7:4
DOWNSEL
0x0
RW
Calibration Down-counter Select
Selects clock source for the calibration down-counter. Only change when calibration circuit is off.
Value
Mode
Description
0
HFCLK
Select HFCLK for down-counter
1
HFXO
Select HFXO for down-counter
2
LFXO
Select LFXO for down-counter
3
HFRCO
Select HFRCO for down-counter
4
LFRCO
Select LFRCO for down-counter
5
AUXHFRCO
Select AUXHFRCO for down-counter
6
PRS
Select PRS input selected by PRSDOWNSEL as down-counter
3:0
UPSEL
0x0
RW
Calibration Up-counter Select
Selects clock source for the calibration up-counter. Only change when calibration circuit is off.
Value
Mode
Description
0
HFXO
Select HFXO as up-counter
1
LFXO
Select LFXO as up-counter
2
HFRCO
Select HFRCO as up-counter
3
LFRCO
Select LFRCO as up-counter
4
AUXHFRCO
Select AUXHFRCO as up-counter
5
PRS
Select PRS input selected by PRSUPSEL as up-counter
Reference Manual
CMU - Clock Management Unit
silabs.com
| Building a more connected world.
Rev. 1.1 | 325