22.5.2 CRYOTIMER_PERIODSEL - Interrupt Duration
Offset
Bit Position
0x004
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0x20
Access
R
W
Name
Bit
Name
Reset
Access Description
31:6
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
5:0
PERIODSEL
0x20
RW
Interrupts/Wakeup Events Period Setting
Defines the duration between the Interrupts/Wakeup events based on the pre-scaled clock.
Value
Description
0
Wakeup event after every Pre-scaled clock cycle.
1
Wakeup event after 2 Pre-scaled clock cycles.
2
Wakeup event after 4 Pre-scaled clock cycles.
3
Wakeup event after 8 Pre-scaled clock cycles.
4
Wakeup event after 16 Pre-scaled clock cycles.
5
Wakeup event after 32 Pre-scaled clock cycles.
6
Wakeup event after 64 Pre-scaled clock cycles.
7
Wakeup event after 128 Pre-scaled clock cycles.
8
Wakeup event after 256 Pre-scaled clock cycles.
9
Wakeup event after 512 Pre-scaled clock cycles.
10
Wakeup event after 1k Pre-scaled clock cycles.
11
Wakeup event after 2k Pre-scaled clock cycles.
12
Wakeup event after 4k Pre-scaled clock cycles.
13
Wakeup event after 8k Pre-scaled clock cycles.
14
Wakeup event after 16k Pre-scaled clock cycles.
15
Wakeup event after 32k Pre-scaled clock cycles.
16
Wakeup event after 64k Pre-scaled clock cycles.
17
Wakeup event after 128k Pre-scaled clock cycles.
18
Wakeup event after 256k Pre-scaled clock cycles.
19
Wakeup event after 512k Pre-scaled clock cycles.
20
Wakeup event after 1M Pre-scaled clock cycles.
21
Wakeup event after 2M Pre-scaled clock cycles.
22
Wakeup event after 4M Pre-scaled clock cycles.
Reference Manual
CRYOTIMER - Ultra Low Energy Timer/Counter
silabs.com
| Building a more connected world.
Rev. 1.1 | 750