Bit
Name
Reset
Access Description
Value
Mode
Description
0
NORMAL
Module not in reset
1
RESET
The continuous test, the conditioning function and the FIFO are reset
7
FULLIEN
0
RW
Interrupt Enable for FIFO Full
Enable/Disable FIFO full interrupt.
6
APT4096IEN
0
RW
Interrupt Enable for Adaptive Proportion Test Failure (4096-sample
Window)
Enable/Disable 4096-sample Adaptive Proportion test failure interrupt.
5
APT64IEN
0
RW
Interrupt Enable for Adaptive Proportion Test Failure (64-sample
Window)
Enable/Disable 64-sample Adaptive Proportion test failure interrupt.
4
REPCOUNTIEN
0
RW
Interrupt Enable for Repetition Count Test Failure
Enable/Disable Repetition Count Test failure interrupt.
3
CONDBYPASS
0
RW
Conditioning Bypass
Enables bypassing of the conditioning function (to observe entropy source directly).
Value
Mode
Description
0
NORMAL
The conditionig function is used
1
BYPASS
The conditioning function is bypassed
2
TESTEN
0
RW
Test Enable
Selects the input for the conditioning function and continuous tests.
Value
Mode
Description
0
NOISE
Non-determinsitc random number generation
1
TESTDATA
Pseudo-random number generation
1
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
0
ENABLE
0
RW
TRNG Module Enable
Enable the TRNG. The module will generate random numbers unless the FIFO is full.
Value
Mode
Description
0
DISABLED
Module disabled
1
ENABLED
Module enabled
Reference Manual
TRNG - True Random Number Generator
silabs.com
| Building a more connected world.
Rev. 1.1 | 1017