e = abs(V
out
/(V
REF
* 0.8) - 1)
Figure 23.7. Calibration Error
where V
out
is the measured voltage at the pin and V
REF
is the reference voltage.
Note that even if only CH1 is going to be used, the full calibration procedure should be followed. It is permissible to skip CH1 calibration
if only CH0 is used. The following parameters influence the calibration. A change in any of these might require a re-calibration:
• VDACn_CTRL.REFSEL
• VDACn_OPAx_OUT.MAINOUTEN
• VDACn_OPAx_OUT.ALTOUTEN
• VDACn_OPAx_CTRL.DRIVESTRENGTH
23.3.20 Warmup Mode
If the WARMUPMODE field in VDACn_CTRL is set to KEEPINSTANDBY, the VDAC keeps internal bias currents running between con-
versions. It does not reduce the startup time, but it can help reduce noise from the VDAC to other analog peripherals, like the ADC or
ACMP.
Reference Manual
VDAC - Digital to Analog Converter
silabs.com
| Building a more connected world.
Rev. 1.1 | 762