Remedy:
- re-commission the safety functions.
- upgrade the drive software.
- replace the memory card or drive.
For fault value = 129:
- activate the Safety Integrated commissioning mode.
- adapt the PROFIsafe address.
- copy the safety parameters and confirm the data change.
- exit the Safety Integrated commissioning mode.
- save all parameters or "Copy RAM to ROM".
- carry out a POWER ON (switch-off/switch-on).
Note:
SI: Safety Integrated
F30657
SI P2: PROFIsafe telegram number invalid
Message value:
-
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
POWER ON
Cause:
The PROFIsafe telegram number that has been set is not valid.
When PROFIsafe is enabled (p9601.3 = 1), then a telegram number greater than zero must be used.
The copy function was not used.
Note:
This fault does not result in a safety stop response.
See also: p9611, p60022, r60022
Remedy:
Enter a valid PROFIsafe telegram number (p9611), then using the commissioning tool, copy the safety parameters and
confirm the data change.
F30659
SI P2: Write request for parameter rejected
Message value:
%1
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The write request for one or several Safety Integrated parameters in monitoring channel 2 was rejected.
Note:
See also fault F01659.
Remedy:
Upgrade the firmware to later version.
F30664
Error while booting
Message value:
%1
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
POWER ON
Cause:
An error has occurred during booting.
Fault value (r0949, interpret hexadecimal):
Only for internal Siemens troubleshooting.
Remedy:
- carry out a POWER ON (switch-off/switch-on).
- upgrade firmware to later version.
- contact Technical Support.
Faults and alarms
13.2 List of faults and alarms
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
525
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......