p0489[0...2]
Activate measuring probe 2
Changeable: T, U
Data type: Integer16
P group: Encoder
Min: 0
Max: 211
Def: 0
Description:
Setting to activate/de-activate measuring probe 2.
The inversion of probe 2 is set in p0490.1.
Value:
0:
No measuring probe
211:
DI 1 (X130 / 1.5)
Index:
[0] = Encoder 1
[1] = Reserved
[2] = Reserved
Dependency:
See also: p0488, p0490
CAUTION
In order to prevent incorrect measurement values, these parameters may not be written during an active
measurement.
Note
DI: Digital Input
Refer to the encoder interface for PROFIdrive.
p0490
Invert measuring probe
Changeable: T, U
Data type: Unsigned32
P group: Encoder
Min: -
Max: -
Def: 0000 bin
Description:
Setting to invert digital input 0 or 1 (probe 1, 2).
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (X130 / 1.2)
Inverted
Not inverted
-
01
DI 1 (X130 / 1.5)
Inverted
Not inverted
-
Dependency:
See also: p0488, p0489
Note
DI: Digital Input
The inversion has no effect on the status display of the digital inputs (r0722).
r0550[0]
Brake status
Data type: Integer16
P group: Motor
Description:
Displays the status of the brake.
The value of r0550 is read when the drive powers up.
Value:
0:
No data
1:
Holding brake
Dependency:
See also: p1215, p1216, r1216, p1217, r1217
p0613[0]
Motor temperature model ambient temperature
Changeable: C2(3), T, U
Data type: FloatingPoint32
P group: Motor
Min: -40 [°C]
Max: 100 [°C]
Def: 20 [°C]
Description:
Sets the motor ambient temperature.
Based on this value, the motor temperature model calculates the thermal motor utilization (r0034).
Dependency:
See also: r0034
See also: F07011, A07012
r0722
Digital inputs status
Data type: Unsigned32
P group: Commands
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
237
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......