12:
STOP C with delayed stop response when the bus fails
13:
STOP D with delayed stop response when the bus fails
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLS4
Dependency:
See also: p9531, p9580
Note
In an extended sense, bus failure is interpreted here as a communication error in the control signals of the safety
functions (e.g. via PROFIsafe).
SLS: Safely Limited Speed
p9564
SI Motion SDI tolerance
Changeable: C2(95)
Data type: FloatingPoint32
P group: Safety Integrated
Min: 0.001 [mm]
Max: 360.000 [mm]
Def: 12.000 [mm]
Description:
Sets the tolerance for the "SDI" function.
This motion in the monitored direction is still permissible before safety message C01716 is initiated.
Dependency:
See also: p9565, p9566
See also: C01716
Note
SDI: Safe Direction (safe motion direction)
p9565
SI Motion SDI delay time
Changeable: C2(95)
Data type: FloatingPoint32
P group: Safety Integrated
Min: 0.00 [ms]
Max: 600000.00 [ms]
Def: 100.00 [ms]
Description:
Sets the delay time for the "SDI" function.
After selecting the SDI function, then for a maximum of this time, motion in the monitored direction is permissible. This
time can therefore be used for braking any motion.
Dependency:
See also: p9564, p9566
See also: C01716
Note
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SDI: Safe Direction (safe motion direction)
p9566
SI Motion SDI stop response
Changeable: C2(95)
Data type: Integer16
P group: Safety Integrated
Min: 0
Max: 13
Def: 1
Description:
Sets the stop response for the "SDI" function.
This setting applies to both directions of motion.
Value:
0:
STOP A
1:
STOP B
2:
STOP C
3:
STOP D
10:
STOP A with delayed stop response when the bus fails
11:
STOP B with delayed stop response when the bus fails
12:
STOP C with delayed stop response when the bus fails
13:
STOP D with delayed stop response when the bus fails
Dependency:
See also: p9564, p9565
See also: C01716
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
271
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......