No.
Fault cause
Remedial measures
I
Heat dissipation impeded by deposits
Clean the surface of the drives and ensure that the cooling air can flow
in and out unimpeded
Cooling air inlet/outlet is blocked by for‐
eign bodies
Remove the reason for the blocking and ensure that the cooling air can
flow in and out unimpeded
J
Insufficient shielding for motor and/or en‐
coder cable
Check the shielding and grounding
K
Excessive drive controller gain
Adjust the controller
L
Rotating parts are grinding
Determine cause and adjust parts
Foreign bodies inside the motor
Replace the motor
Bearing damage
Replace the motor
M
Rotor not balanced
Replace the motor
N
Rotor out of true, shaft bent
Consult the manufacturer
O
Poor alignment
Align motor set, check coupling
P
Coupled machine not balanced
Re-balance coupled machine
Q
Shocks from coupled machine
Check coupled machine
R
Fault originating from the gearbox
Adjust/repair gearbox
If the fault still cannot be resolved after taking the measures stated above, please contact the
manufacturer or the Siemens Service Center.
Diagnostics
7.3 Correcting faults on the motor
SINAMICS S210 servo drive system
172
Operating Instructions, 12/2017, A5E41702836B AA
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......