![Siemens SIMOTICS S-1FK2 Скачать руководство пользователя страница 288](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045288.webp)
Note
The test torque effective for the brake test can be set for each sequence using a factor (p10210, p10220).
p10210[0...1]
SI Motion SBT test torque factor sequence 1
Changeable: C2(95)
Data type: FloatingPoint32
P group: Safety Integrated
Min: 0.30
Max: 1.00
Def: 1.00
Description:
Sets the factor for the test torque of sequence 1 for the safe brake test.
The factor is referred to the holding torque of the brake (p10209).
Index:
[0] = Brake 1
[1] = Reserved
Dependency:
See also: p10209
p10211[0...1]
SI Motion SBT test duration sequence 1
Changeable: C2(95)
Data type: FloatingPoint32
P group: Safety Integrated
Min: 20 [ms]
Max: 10000 [ms]
Def: 1000 [ms]
Description:
Sets the test duration for sequence 1 for the safe brake test.
The test torque is available for this time at the closed brake.
Index:
[0] = Brake 1
[1] = Reserved
Note
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
p10212[0...1]
SI Motion SBT position tolerance sequence 1
Changeable: C2(95)
Data type: FloatingPoint32
P group: Safety Integrated
Min: 0.001 [mm]
Max: 360.000 [mm]
Def: 1.000 [mm]
Description:
Sets the tolerated position deviation for sequence 1 for the safe brake test.
Index:
[0] = Brake 1
[1] = Reserved
p10218
SI Motion SBT test torque sign
Changeable: C2(95)
Data type: Integer16
P group: Safety Integrated
Min: 0
Max: 1
Def: 0
Description:
Sets the sign for the test torque for the safe brake test.
Value:
0:
Positive
1:
Negative
p10220[0...1]
SI Motion SBT test torque factor sequence 2
Changeable: C2(95)
Data type: FloatingPoint32
P group: Safety Integrated
Min: 0.30
Max: 1.00
Def: 1.00
Description:
Sets the factor for the test torque of sequence 2 for the safe brake test.
The factor is referred to the holding torque of the brake (p10209).
Index:
[0] = Brake 1
[1] = Reserved
Dependency:
See also: p10209
p10221[0...1]
SI Motion SBT test duration sequence 2
Changeable: C2(95)
Data type: FloatingPoint32
P group: Safety Integrated
Min: 20 [ms]
Max: 10000 [ms]
Def: 1000 [ms]
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
286
Operating Instructions, 12/2017, A5E41702836B AA
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......