![Siemens SIMOTICS S-1FK2 Скачать руководство пользователя страница 244](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045244.webp)
Note
Example:
r0975[0] = 42 --> SIEMENS
r0975[1] = 11 --> SERVO drive object type
r0975[2] = 102 --> first part, firmware version V01.02 (second part, refer to index 10)
r0975[3] = 2003 --> year 2003
r0975[4] = 1401 --> 14th of January
r0975[5] = 1 --> PROFIdrive drive object, type class
r0975[6] = 9 --> PROFIdrive drive object sub-type class 1
r0975[7] = 2 --> drive object number = 2
r0975[8] = 0 (reserved)
r0975[9] = 0 (reserved)
r0975[10] = 600 --> second part, firmware version (complete version: V01.02.06.00)
p0976
Reset all parameters
Changeable: C1(30)
Data type: Unsigned16
P group: Factory settings
Min: 0
Max: 1
Def: 0
Description:
Resets all parameters of the drive system.
Value:
0:
Inactive
1:
Start reset of all parameters to factory setting
Dependency:
See also: p0977
NOTICE
After changing the value, it is not possible to change parameters until the operation has been completed.
Note
After all of the parameters have been reset to their factory setting, the system must be commissioned for the first time
again.
Reset is realized in the non-volatile memory.
Procedure:
1. Set p0009 = 30 (parameter reset).
2. Set p0976 = 1 The system is powered up again.
p0976 is automatically set to 0 and p0009 is automatically set to 1 after this has been carried out.
p0977
Save all parameters
Changeable: T, U
Data type: Unsigned16
P group: Factory settings
Min: 0
Max: 1
Def: 0
Description:
Saves all parameters of the drive system to the non-volatile memory.
When saving, only the adjustable parameters intended to be saved are taken into account.
Value:
0:
Inactive
1:
Save in non-volatile memory - loaded at POWER ON
Dependency:
See also: p0976
NOTICE
The drive power supply may only be switched off after data has been saved (i.e. after data save has been started,
wait until the parameter again has the value 0).
Writing to parameters is inhibited while saving.
r0979[0...30]
PROFIdrive encoder format
Data type: Unsigned32
P group: Encoder
Description:
Displays the actual position encoder used according to PROFIdrive.
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
242
Operating Instructions, 12/2017, A5E41702836B AA
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......