![Siemens SIMOTICS S-1FK2 Скачать руководство пользователя страница 265](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045265.webp)
Note
For the commissioning tool, after changing over the axis type, the units dependent on the axis type are only updated
after a project upload.
A change only becomes effective after a POWER ON.
p9505
SI Motion SP modulo value is
Changeable: C2(95)
Data type: FloatingPoint32
P group: Safety Integrated
Min: 0 [°]
Max: 737280 [°]
Def: 0 [°]
Description:
Sets the modulo value in degrees for rotary axes of the "Safe position" function.
This modulo value is taken into account when safely referencing as well as when transferring the safe position via
PROFIsafe when the absolute position is enabled.
The value should be set, so that it is precisely at 2^n revolutions, so that when the range that can be represented
(+/-2048) overflows, this does not cause the position actual value to jump.
The modulo function is deactivated for a value = 0.
Dependency:
See also: p9501
See also: F01681
NOTICE
When the "SLP" function is activated, the modulo function must be deactivated as otherwise fault F01681 will be
output.
If the absolute position is not enabled, then the parameterized modulo value is not taken into account.
Note
SLP: Safely Limited Position
SP: Safe Position
p9506
SI Motion function specification
Changeable: C2(95)
Data type: Integer16
P group: Safety Integrated
Min: 0
Max: 2
Def: 0
Description:
Sets the function specification for the safe motion monitoring.
Value:
0:
Safety with encoder and accel_monitoring (SAM) / delay time
2:
Safety with encoder with brake ramp (SBR)
Dependency:
See also: C01711
Note
A change only becomes effective after a POWER ON.
p9507
SI Motion function configuration
Changeable: C2(95)
Data type: Unsigned32
P group: Safety Integrated
Min: -
Max: -
Def: 0100 0001 bin
Description:
Sets the function configuration for the safe motion monitoring functions.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Extended message acknowledgment
Yes
No
-
01
Setpoint velocity limit for STOP F
No
Yes
-
03
SS1 with OFF3 (brake response)
SS1E external stop SS1 with OFF3
-
Dependency:
See also: C01711
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
263
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......