![Siemens SIMOTICS S-1FK2 Скачать руководство пользователя страница 284](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045284.webp)
r9733[0...2]
SI Motion setpoint speed limit effective
Data type: FloatingPoint32
P group: Safety Integrated
Scaling: p2000
Description:
Displays the necessary setpoint speed limit as a result of the selected motion monitoring functions.
Contrary to the parameterization of the SI limit values, this parameter specifies the motor-side limit value and not the
load-side limit value.
Index:
[0] = Setpoint limiting positive
[1] = Setpoint limiting negative
[2] = Setpoint limit absolute
Dependency:
For SLS: r9733[0] = p9531[x] x p9533 (converted from the load side to the motor side)
For SDI negative: r9733[0] = 0
For SLS: r9733[1] = - p9531[x] x p9533 (converted from the load side to the motor side)
For SDI positive: r9733[1] = 0
[x] = Selected SLS stage
Conversion factor from the motor side to the load side:
- motor type = rotary and axis type = linear: p9522 / (p9521 x p9520)
- otherwise: p9522 / p9521
See also: p9531, p9533
Note
This parameter is not influenced by setting the axis type (p9502).
If the "SLS" or "SDI" function is not selected, r9733[0] shows p1082 and r9733[1] shows -p1082.
The display in r9733 can be delayed by up to one Safety monitoring clock cycle as compared to the display in r9719/
r9720 and r9721/r9722.
When selecting SOS or a STOP A ... D, setpoint 0 is specified in r9733.
r9734
SI Safety Info Channel status word S_ZSW1B
Data type: Unsigned16
P group: Safety Integrated
Description:
Display for the status word of safety functions (S_ZSW1B).
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
STO active
Yes
No
-
01
SS1 active
Yes
No
-
02
SS2 active
Yes
No
-
03
SOS active
Yes
No
-
04
SLS active
Yes
No
-
05
SOS selected
Yes
No
-
06
SLS selected
Yes
No
-
07
Internal event
Yes
No
-
09
Select SLS bit0
Yes
No
-
10
Select SLS bit1
Yes
No
-
12
SDI positive selected
Yes
No
-
13
SDI negative selected
Yes
No
-
15
Safety message present
Yes
No
-
Note
For bit 07:
An internal event is displayed if a STOP A ... F is active.
r9743
SI Safety Info Channel status word S_ZSW2B
Data type: Unsigned16
P group: Safety Integrated
Description:
Display for the status word of the safety functions (S_ZSW2B).
Bit field:
Bit
Signal name
1 signal
0 signal
FP
08
SDI positive selected
Yes
No
-
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
282
Operating Instructions, 12/2017, A5E41702836B AA
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......