![Siemens SIMOTICS S-1FK2 Скачать руководство пользователя страница 281](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045281.webp)
18
Actual value > upper limit SSM-
Yes
No
-
19
Actual value > lower limit SSM-
Yes
No
-
20
Actual value > upper limit modulo
Yes
No
-
21
Actual value > lower limit modulo
Yes
No
-
Dependency:
See also: C01711
Note
SSM: Safe Speed Monitor (safety-relevant feedback signal from the speed monitoring)
r9712
SI Motion diagnostics position actual value motor side
Data type: Unsigned32
P group: Safety Integrated
Description:
Displays the position actual value on the motor side for motion monitoring functions.
Note
The display is updated in the safety monitoring clock cycle.
r9713[0...5]
SI Motion diagnostics position actual value load side
Data type: Integer32
P group: Safety Integrated
Description:
Display and connector output for the actual load-side actual values of both monitoring channels and their difference.
Index:
[0] = Load-side actual value on the CU
[1] = Load-side actual value on the second channel
[2] = Load-side actual value difference CU - second channel
[3] = Load-side max. actual value difference CU - second channel
[4] = Reserved
[5] = Reserved
Dependency:
See also: r9708
Note
Regarding the units, this parameter should be interpreted as follows:
- linear axis: µm
- rotary axis: mdegrees
The value of this parameter is displayed in r9708 with units (mm or degrees).
The display is updated in the safety monitoring clock cycle.
For index [0]:
The display of the load-side position actual value on the first channel is updated in the monitoring clock cycle.
For index [1]:
The display of the load-side position actual value on the second channel is updated in the KDV clock cycle (r9724)
and delayed by one KDV clock cycle.
For index [2]:
The difference between the load-side position actual value in the first channel and load-side position actual value in
the second channel is updated in the KDV clock cycle (r9724) and delayed by one KDV clock cycle.
For index [3]:
The maximum difference between the load-side position actual value in the first channel and the load-side position
actual value in the second channel.
KDV: Data cross-check
r9714[0...3]
SI motion diagnostics velocity
Data type: FloatingPoint32
P group: Safety Integrated
Description:
Displays the velocity actual values for motion monitoring functions.
Index:
[0] = Load side speed actual value
[1] = Actual SAM/SBR speed limit
[2] = Actual SLS speed limit
[3] = Reserved
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
279
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......