![Siemens SIMOTICS S-1FK2 Скачать руководство пользователя страница 446](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045446.webp)
Remedy:
Check the encoder selection configuration (p1192).
Note:
If there is no encoder and connector input p1191 (DSC position controller gain) is interconnected, then connector input
p1191 must have a 0 signal.
F07430
Drive: Changeover to open-loop torque controlled operation not possible
Message value:
-
Drive object:
All objects
Reaction:
OFF2 (NONE, OFF1, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
For encoderless operation, the converter cannot change over to closed-loop torque-controlled operation (BI: p1501).
Remedy:
Do not attempt to cover over to closed-loop torque-controlled operation.
F07431
Drive: Changeover to encoderless operation not possible
Message value:
-
Drive object:
All objects
Reaction:
OFF2 (OFF1)
Acknowledge:
IMMEDIATELY
Cause:
For closed-loop torque control, the converter cannot change over to encoderless operation (p1404).
Remedy:
Do not attempt to change over to encoderless operation.
F07432
Drive: Motor without overvoltage protection
Message value:
%1
Drive object:
All objects
Reaction:
OFF2 (OFF1)
Acknowledge:
IMMEDIATELY
Cause:
In the case of a fault at maximum speed, the motor can generate an overvoltage that can destroy the drive system.
Fault value (r0949, interpret hexadecimal):
Associated Drive Data Set (DDS).
Faults and alarms
13.2 List of faults and alarms
SINAMICS S210 servo drive system
444
Operating Instructions, 12/2017, A5E41702836B AA
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......