![Siemens SIMOTICS S-1FK2 Скачать руководство пользователя страница 130](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045130.webp)
Setting digital inputs
1. Select "Parameters" and "Inputs" in the navigation.
Figure 6-13
Digital inputs
2. Select the appropriate input signal in the table for the measuring inputs and the temperature
control:
– "Digital input 0 (X130/DI 0)": Probe 1
– "Digital input 1 (X130/DI 1)": Probe 2
– "Digital input 2, 3 (X130/DI 2+, DI 2-, DI 3+, DI 3-)":
Fail-safe digital input for the Safety Integrated Basic Function "STO" or "SS1".
The configuration is performed via the Safety commissioning. By clicking "Safety", you
open the Safety commissioning and can make the appropriate settings there.
"Safety commissioning (Page 135)"
– "Digital input 4 (X130/DI 4)": Temperature monitoring of ext. braking resistor
3. Click
to save the data permanently.
Commissioning and diagnostics in the Web server
6.6 Settings
SINAMICS S210 servo drive system
128
Operating Instructions, 12/2017, A5E41702836B AA
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......