Cause:
There is not sufficient memory space in the NVRAM on the drive to save parameters r9781 and r9782 (safety logbook).
Note:
This fault does not result in a safety stop response.
Fault value (r0949, interpret decimal):
1: There is no longer any free memory space in the NVRAM.
Remedy:
For fault value = 1:
- de-select functions that are not required and that take up memory space in the NVRAM.
- contact Technical Support.
Note:
NVRAM: Non-Volatile Random Access Memory (non-volatile read and write memory)
A01691 (F)
SI Motion: Ti and To unsuitable for PN cycle
Message value:
-
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
The configured times for PROFINET communication are not permitted and the PN cycle is used as the actual value
acquisition cycle for the safe movement monitoring functions:
Isochronous PROFINET:
The sum of Ti and To is too high for the selected PN cycle. The PN clock cycle should be at least 1 current controller cycle
greater than the sum of Ti and To.
No isochronous PROFINET:
The PN clock cycle must be at least 4x the current controller clock cycle.
Notice:
If this alarm is not observed, then message C01711 or C30711 – with the value 1020 ... 1021 – can sporadically occur.
Remedy:
Configure Ti and To low so that they are suitable for the PN cycle or increase the PN cycle time.
Reaction upon F: NONE (OFF1, OFF2, OFF3)
Acknowl. upon F: IMMEDIATELY (POWER ON)
F01692
SI Motion P1 (CU): Parameter value not permitted for encoderless
Message value:
Parameter: %1
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The parameter cannot be set to this value if encoderless motion monitoring functions have been selected in p9506.
Note:
This fault does not result in a safety stop response.
Fault value (r0949, interpret decimal):
Parameter number with the incorrect value.
See also: p9501
Remedy:
- correct the parameter specified in the fault value.
- if necessary, de-select encoderless motion monitoring functions (p9506).
See also: p9501
A01693 (F)
SI P1 (CU): Safety parameter setting changed, warm restart/POWER ON required
Message value:
%1
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Faults and alarms
13.2 List of faults and alarms
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
373
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......