Remote control commands
R&S
®
SMM100A
747
User Manual 1179.1341.02 ─ 05
Parameters:
<Peak>
float
Range:
-60 to 3.02
Increment: 0.01
*RST:
0
Default unit: dBfs
Example:
See
Example "Applying an external digital baseband signal (Dig
[:SOURce<hw>]:BBIN:POWer:RMS?
Queries the RMS level of the external digital baseband signal.
Return values:
<Rms>
float
Range:
-100 to 10
Increment: 0.01
*RST:
0
Example:
See
Example "Applying an external digital baseband signal (Dig
Usage:
Query only
13.16.3
Analog modulation subsystems
Option: see
Chapter 7.11, "Analog modulations"
The subsystems in this section describe all commands for analog modulation of the RF
signal. Divided in separate sections, you can configure amplitude modulation (AM), fre-
quency modulation (FM) , phase modulation (PhiM) and pulse modulation (PULM).
You can perform each of the modulations either with an internally generated modula-
tion signal or with an externally applied signal.
To configure the internal signal, use the commands listed in
For more information:
Chapter 7.11, "Analog modulations"
13.16.3.1
SOURce:MODulation subsystem
The command in this subsytem allows you to disable all active modulations at once,
and, vice versa, to restore the last active ones.
[:SOURce<hw>]:MODulation[:ALL][:STATe]
<State>
Activates all modulations that were active before the last switching off.
SOURce subsystem