Remote control commands
R&S
®
SMM100A
818
User Manual 1179.1341.02 ─ 05
Parameters:
<SMode>
SAME | NEXT | SEQuencer | NSEam
NSEam = Next Segment Seamless
*RST:
NEXT
Example:
See
Example "Configuring the output order of the segments"
Manual operation:
See
Multi-segment sequencing commands
Required options
See
Chapter 4.9.1, "Required options"
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:BLANk:APPend
..............................818
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CATalog?
.......................................819
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk
.......................................... 819
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk:MODE
............................... 819
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:LEVel[:MODE]
................................819
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:COMMent
...................................... 820
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:DELete
..........................................820
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:OFILe
............................................820
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SEGMent:APPend
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SELect
.......................................... 821
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:BLANk:APPend
<SampCount>, <Frequency>
Adds a blank segment to the multi-segment file.
Setting parameters:
<SampCount>
float
Specifies the number of samples.
Range:
512 to 1E7
Increment: 1
*RST:
1000
<Frequency>
float
Determines the clock rate.
Range:
400 Hz to depends on the installed options
Increment: 0.001
*RST:
1E8
Example:
See
Example "Creating a multi-segment waveform"
Usage:
Setting only
Manual operation:
See
SOURce subsystem