![Rohde & Schwarz SMM100A Скачать руководство пользователя страница 229](http://html.mh-extra.com/html/rohde-and-schwarz/smm100a/smm100a_user-manual_1477939229.webp)
Configuring the internal baseband source
R&S
®
SMM100A
229
User Manual 1179.1341.02 ─ 05
Table 4-18: Waveform triggering: "Next Trigger Mode = Next Segment", "Trigger Source = External"
"Trigger Mode"
Description
"Auto"
Output starts at once and the segment is generated continuously.
Further trigger events are ignored. Each next segment trigger event switches over
to outputting the subsequent segment, following a system-imposed signal gap.
If the segment index is changed in "Segment", output of the current segment is
stopped and the new segment is output immediately, following a system-imposed
signal gap.
The subsequent trigger event after the last segment causes the first segment to be
output again.
"Armed_Auto"
Output starts after the first trigger event. The segment is then generated continu-
ously.
Further trigger events are ignored. Each next segment trigger event switches over
to outputting the subsequent segment, following a system-imposed signal gap.
If the segment is changed in "Segment", signal output is stopped and the new seg-
ment is not output until a trigger occurs.
The subsequent trigger event after the last segment causes the first segment to be
output again.
"Single"
Output starts after the first trigger event. The segment is then generated once.
Each trigger event (re-) starts the segment; each next segment trigger event
switches over to outputting the subsequent segment.
If the segment is changed in "Segment", signal output is not stopped. The new
segment is not output until a trigger occurs.
The subsequent trigger event after the last segment causes the first segment to be
output again.
For description of the "Retrigger" and "Armed_Retrigger" trigger modes, see
.
4.9.5.3
Triggering in "Next trigger mode = next segment seamless"
The segment selected under "Segment" is output. This mode is only available if all
segments have the same sample rate.
Generating multi-segment waveform files