Example: Global connectors settings configuration
SOURce1:INPut:USER1:DIRection INP
SOURce1:INPut:USER1:SIGNal TRIG1
SOURce1:INPut:USER3:DIRection INP
SOURce1:INPut:USER3:SIGNal NSEGM1
SOURce1:INPut:USER5:DIRection INP
SOURce1:INPut:USER5:SIGNal TRIG2
SOURce1:INPut:USER:TRIGger:LEVel 1.5
SOURce1:INPut:USER:PULM:LEVel 2
// the signal threshold at USER 1-3 is 1.5 V
// this applies to all input signal, i.e. TRIG1 and NSEGM1
// the signal threshold at USER 4-6 is 2 V
// this applies to all input signal, i.e. IPULSA and TRIG2
SOURce1:INPut:USER1:TRIGger:IMPedance G1K
SOURce1:INPut:USER1:TRIGger:SLOPe POS
SOURce1:INPut:USER2:DIRection OUTP
OUTPut1:USER2:SIGNal MARKA2
SOURce1:INPut:USER6:DIRection OUTP
OUTPut1:USER6:SIGNal MTR
OUTPut1:USER6:TRIGger:IMMediate
SOURce1:INPut:USER5:DIRection OUTP
OUTPut1:USER5:SIGNal MTR
OUTPut1:USER5:TRIGger:IMMediate
[:SOURce<hw>]:INPut:TM<ch>:DIRection
........................................................................733
....................................................................................733
[:SOURce]:INPut:USER<ch>:DIRection
............................................................................733
....................................................................................... 733
[:SOURce<hw>]:INPut:TM<ch>:SIGNal
............................................................................733
........................................................................................734
[:SOURce]:INPut:USER<ch>:SIGNal
............................................................................... 735
........................................................................................... 735
:OUTPut:USER<ch>:TRIGger[:IMMediate]
....................................................................... 736
[:SOURce]:INPut:USER:CLOCk:LEVel
............................................................................. 737
[:SOURce]:INPut:USER:TRIGger:LEVel
........................................................................... 737
[:SOURce]:INPut:USER:PULM:LEVel
...............................................................................737
[:SOURce]:INPut:USER:CLOCk:IMPedance
..................................................................... 737
[:SOURce]:INPut:USER:TRIGger:IMPedance
................................................................... 737
[:SOURce]:INPut:USER:CLOCk:SLOPe
........................................................................... 737
[:SOURce]:INPut:USER:TRIGger:SLOPe
......................................................................... 738
[:SOURce<hw>]:INPut:TM:CLOCk:LEVel
......................................................................... 738
[:SOURce<hw>]:INPut:TM:TRIGger:LEVel
........................................................................738
[:SOURce<hw>]:INPut:TM:CLOCk:IMPedance
................................................................. 738
[:SOURce<hw>]:INPut:TM:TRIGger:IMPedance
................................................................738
[:SOURce<hw>]:INPut:TM:CLOCk:SLOPe
....................................................................... 739
[:SOURce<hw>]:INPut:TM:TRIGger:SLOPe
......................................................................739
SOURce subsystem