Configuring the internal baseband source
R&S
®
SMM100A
137
User Manual 1179.1341.02 ─ 05
2. To enable the R&S
SMM100A to use the data list as data source for any of the digi-
tal standards:
a) Select the "Data List Name" in the individual dialog.
For example, for "Baseband > 3GPP FDD > Basestations > BS1 > Channel
Table > P-CCPCH > Data = Data List"
b) Select "DList = None".
c) Select the file in the file system.
4.5.5
References
Table 4-5: Custom digital modulation default values
Parameter
Value
"State"
Not affected
"Data Source"
"PRBS 9"
"Standard"
"GSM"
"Symbol Rate"
"270.833 ksymb/s"
"Coding"
"GSM"
"Modulation Type"
"MSK"
"Filter"
"Gauss (FSK)"
Filter parameter "B*T"
"0.3"
Trigger
"Mode > Auto", "Source > Internal"
Clock
"Source > Internal"
"Power Ramp Control" settings:
"Attenuation"
"15.0 dB"
"Ramp Time"
"1.00 sym"
"Ramp Function"
"Cosine"
"Rise Delay"
"0.00 sym"
"Fall Delay"
"0.00 sym"
"Source"
"Internal"
"State"
"Off"
Table 4-6: Communication standards with their predefined settings
Standard
Modulation
Symbol rate
Filter
Coding
Parameter for SCPI
command
CW in Baseband
BPSK
1 Msym/s
Gauss, B*T = 0.5
Off
CWBPsk
APCO Phase1
C4FM
4FSK Deviation 1.8
kHz
4.8 ksym/s
APCO25, roll off = 0.2
APCO25(FSK)
APCOPH1C4fm
Generating custom digital modulated signals