Configuring the internal baseband source
R&S
®
SMM100A
189
User Manual 1179.1341.02 ─ 05
EQUALRMS
Segments are output so that all segments have the same RMS
value. The value displayed with the parameter "Task bar >
Level" applies to all segments.
Example:
{MWV_SEGMENT_LEVEL_MODE: UNCHANGED}
Usage:
Setting only
{MWV_SEGMENT_LEVEL_OFFS:
RMSOffs_dBSg0,PeakOffs_dBSg0, …, RMSOffs_dBSgN-1, PeakOffs_dBSgN-1}
(mandatory for multi-segment waveforms)
The tag contains a list of level pairs in ASCII floating point format, one pair for every
segment in the multi-segment waveform. The first value of a level pair defines the rms
offset and the second value the peak offset relative to the 16-bit full scale modulation
(-32767; + 32767) = 0 dB. The meaning of one level value pair is the same as in the
tag for normal waveforms.
Example:
{MWV_SEGMENT_LEVEL_OFFS: 3.0,0.0,6.0,0.0}
2 segments: RMS level of segment 0 is 3 dB below full scale;
RMS level of segment 1 is 6dB below full scale.
Peak level of both segments is 0 dB full scale.
Usage:
Setting only
{MWV_SEGMENT_SETTINGS_FILE: SegSettingFilePath}
(optional for multi-segment waveforms)
The tag contains the file path and filename of the multi-segment file, used for the calcu-
lation of the multi-segment waveform.
Example:
{MWV_SEGMENT_SETTINGS_FILE:
"/var/user/Settings.inf_mswv"}
Multi-segment file path and filename.
Usage:
Setting only
{MWV_SEGMENT_FILES:
“FileNameSeg0.wv”, “FileNameSeg1.wv”, …, “FileNameSegN-1.wv”}
(optional for multi-segment waveforms)
The tag contains a list of file names for every segment in the multi-segment waveform
in ASCII format.
Example:
{MWV_SEGMENT_FILES: "/var/user/temp/sine.wv",
"/var/user/temp/rect.wv"”}
Usage:
Setting only
Using the arbitrary waveform generator (ARB)