![Rohde & Schwarz SMM100A Скачать руководство пользователя страница 247](http://html.mh-extra.com/html/rohde-and-schwarz/smm100a/smm100a_user-manual_1477939247.webp)
Configuring the internal baseband source
R&S
®
SMM100A
247
User Manual 1179.1341.02 ─ 05
6. Select "ARB: Multi Carrier > Carrier Graph" to visualize the configuration.
7. Select "ARB: Multi Carrier > General > Output Settings > Output File" and enter the
name of the output file, for example
4x5MHz_3gpp_1_16
.
8. To trigger signal calculation and to load the waveform in the ARB generator, select
"ARB: Multi Carrier > General > Create/Create and Load" function.
9. Select "ARB > General > Load Waveform".
Confirm that you loaded the generated multi-carrier waveform.
10. Select "ARB > State > On" to enable the ARB generator.
4.11
Generating multi-carrier continuous wave signal
The multi-carrier continuous wave (MCCW) is a firmware option that enables the
R&S
SMM100A to calculate up to 160001 continuous wave signals.
Generating multi-carrier continuous wave signal