![Rohde & Schwarz SMM100A Скачать руководство пользователя страница 325](http://html.mh-extra.com/html/rohde-and-schwarz/smm100a/smm100a_user-manual_1477939325.webp)
Configuring the RF signal
R&S
®
SMM100A
325
User Manual 1179.1341.02 ─ 05
Step / Extern Step mode (Sweep/List)
Figure 7-10: Step / Extern Step mode (sweep / list )
●
The instrument generates the signal step-by-step.
●
Starts signal generation with "State = On".
●
Switches to the next step with a manual action.
If the end value is reached, signal generation starts again from the beginning.
●
Stops signal generation with "State = Off".
●
Trigger sources:
–
The rotary knob at the front panel.
–
The [Arrow] keys at the front panel.
–
The corresponding remote control commands.
–
An externally applied trigger signal.
To step through the sweep frequencies or levels:
●
In manual mode:
–
Set the
–
Use the [Up] and [Down] keys or the rotary knob
●
In remote control mode:
–
Use the commands
[:SOURce<hw>]:FREQuency:MANual
with the
UP
or
DOWN
parameter
Steps that would exceed the sweep range are ignored.
Varying the RF signal in list or sweep mode