Remote control commands
R&S
®
SMM100A
744
User Manual 1179.1341.02 ─ 05
[:SOURce<hw>]:BBIN:CHANnel<ch0>:POWer:RMS
<BbinIqHsChPoRms>
Queries the estimated RMS level.
Parameters:
<BbinIqHsChPoRms> float
Range:
-100 to 10
Increment: 0.01
*RST:
0
Example:
See
Example "Applying an external digital baseband signal (HS
Manual operation:
See
[:SOURce<hw>]:BBIN:CHANnel<ch0>:SRATe
<BbinIqHsChSaRat>
Sets the sample rate per channel.
Parameters:
<BbinIqHsChSaRat> float
Range:
400 to 250E6 ("System Config > Mode =
Advanced")/1250E6 ("System Config > Mode =
Standard")
Increment: 0.001
*RST:
100E6
Example:
See
Example "Applying an external digital baseband signal (HS
Manual operation:
See
[:SOURce<hw>]:BBIN:MODE
<Mode>
Defines that a digital external signal is applied.
Parameters:
<Mode>
DIGital
*RST:
DIGital
Example:
See
Example "Applying an external digital baseband signal (Dig
[:SOURce<hw>]:BBIN:SRATe:SOURce
<Source>
Sets the digital interface used to estimate the sample rate.
Parameters:
<Source>
DIN | HSDin
DIN
Estimates the sample rate based on the digital input signal.
SOURce subsystem