PiXtend V2 -L- Hardware Manual
Property
Value
Comment
Type of interface
serial interface, symmetric
(differential)
wired
Type of connection
Data-Bus / Fieldbus
several participants possible
Standard
CAN 2.0B
29 bit-Identifier
Maximum transfer rate
(theoretically)
1 MBaud
depending on:
- the nature, environment
and length of the cable used
- the software used
- the circuit technology other
participants on the bus
Maximum number of
participants on the bus
(theoretically)
112
Differential output voltage
min. 1.5 V
max. 3 V
at 50 Ω load
without load
minimum differential input
voltage
1 V
"input threshold"
Maximum voltages
+/- 42 V
to CANH or CANL to GND
Short circuit current
max. +/- 200 mA
against a maximum of +/-
42V
Short circuit protection
yes
Short circuit to GND
Overload protection
yes
thermal
Isolation
no
Status display
no
Terminator
yes
120 Ω, by jumper
Permitted cable length
< 3 m
< 30 m
unshielded cables
shielded cables
Table 27: Technical data - CAN
Warning!
Exceeding the specified maximum values may result in transmission
errors, malfunctions and component defects.
www.pixtend.com
Copyright by Qube Solutions GmbH
139 / 146