PiXtend V2 -L- Hardware Manual
Property
Value
Comment
Type of outputs
Relays
electromechanical
for direct voltage (DC) and
alternating voltage (AC)
One changeover contact
each relay
SPDT
Nominal current
6 A
Maximum inrush current
10 A
Maximum voltage (DC)
60 V
Observe safety instructions!
Maximum voltage (AC)
250 V
Observe safety instructions!
Maximum switching
capacities
30 W
72 W
144 W
690 W
1380 W
at 5 V DC
at 12 V DC
at 24 V DC
at 115 V AC (USA)
at 230 V AC (Europa)
Load types
ohmic, inductive, lamp
load
for inductive loads a free-running
diode must be provided
externally
Contact Resistance
~ 100 mΩ
Response time
~ 10 ms
excl. bounce
Fall time
~ 5 ms
excl. bounce
Power consumption
0.25 W
per active relay
Mechanical lifetime
(theoretically)
> 20 x 10
6
switching
cycles
real number depends on the type
of load or switching capacity
Short circuit and
Overload protection
no
a 6 A fuse must be provided
externally
Isolation
yes
All switching contacts are
isolated to GND and all other
signals on PiXtend V2 -L- / RPi
Status display
LED (orange)
Description: „12“ .. „15“ on PCB ,
RELAY0 .. RELAY 3 on hood
Permissible cable length
< 30 m
Table 17: Technical data - relay outputs
www.pixtend.com
Copyright by Qube Solutions GmbH
99 / 146