Coordinates management
104
3 E
therC
Example 2: Coordinates when the wrap setting range is 1,800 rev and the resolution is 10,000 P/R
Index
Sub
Name
Setting value
6091h
01h
Electronic gear A
1
02h
Electronic gear B
1
47F2h
00h
Initial coordinate generation & wrap coordinate setting
1 (Manual setting)
41C7h
00h
Wrap setting
1 (Enable)
41C9h
00h
Initial coordinate generation & wrap setting range
18,000 (1,800 rev)
41CBh
00h
Initial coordinate generation & wrap range offset ratio
5,000 (50.00 %)
41CCh
00h
Initial coordinate generation & wrap range offset value
0 (0 step)
Coordinates example
When the parameters are set as shown in the above table, the motor can be operated on coordinates in the figure.
–4,500,000
4,500,000
0
–9,000,000
0
–4,500,000
8,999,999
4,500,000
–9,000,000
If the Wrap setting (41C7h) or the Initial coordinate generation & wrap setting range (41C9h) is
changed, the absolute position may be shifted. When the parameter is changed, perform the position
preset (P-PRESET) or return-to-home operation.
z
Setting conditions of Initial coordinate generation & wrap setting range (41C9h)
When the wrap range satisfies the following conditions, continuous rotation in the same direction can be performed
while the home is maintained.
Condition 1
1,800 *
Wrap setting range
= To be an integer
Condition 2
Electronic gear B
Electronic gear A
Wrap setting range × Resolution = Wrap setting range ×
× 10,000
* The motors of frame size 20 mm (0.79 in.)
and 28 mm (1.10 in.) are 900.
= To be an integer
If the setting conditions of the Initial coordinate generation & wrap setting range (41C9h) is not
satisfied even when the Wrap setting (41C7h) is set to "1: Enable,” information of the Wrap setting
error will be generated. If the main power supply and the control power supply are turned on again
or Configuration is executed in a state where information of the Wrap setting error is generated, an
alarm of the Wrap setting error will be generated.
Setting example 1
•
Wrap setting range: 100 rev
•
Resolution: 10,000 P/R (electronic gear A=1, electronic gear B=1)
•
Motor: Standard motor (gear ratio 1)
Condition 1
1,800
Wrap setting range
=
= 18
1,800
100
Condition 2
Electronic gear B
Electronic gear A
1
1
Wrap setting range ×
× 10,000 = 100 ×
× 10,000 = 1,000,000
The setting conditions are satisfied since both the conditions (1) and (2) are integers. The wrap function can be used.