Objects of manufacturer-specific area
135
4 Objec
4
Objects of manufacturer-specific area
These are Oriental Motor’s specific objects.
Refer to the
AZ
Series OPERATING MANUAL Function Edition for details of each object. When checking the
AZ
Series
OPERATING MANUAL Function Edition, use the object name instead of the Index.
Index
Sub
Name
Type
Access
PDO
Save
Initial value
Range
Update
4020h
00h
Backup DATA access key
INT32
RW
No
−
0
Key code: 20519253 (01391955h)
A
4021h
00h
Backup DATA write key
INT32
RW
No
−
0
Key code: 1977326743 (75DB9C97h)
A
403Eh
00h
Driver input command
U16
RW
RxPDO
−
0
0000h to FFFFh
A
403Fh
00h
Driver output status
U16
RO
TxPDO
−
−
−
−
4040h
00h
Present alarm
U16
RO
TxPDO
−
−
4041h
00h
Alarm history 1
U16
RO
No
−
−
4042h
00h
Alarm history 2
U16
RO
No
−
−
4043h
00h
Alarm history 3
U16
RO
No
−
−
4044h
00h
Alarm history 4
U16
RO
No
−
−
4045h
00h
Alarm history 5
U16
RO
No
−
−
4046h
00h
Alarm history 6
U16
RO
No
−
−
4047h
00h
Alarm history 7
U16
RO
No
−
−
4048h
00h
Alarm history 8
U16
RO
No
−
−
4049h
00h
Alarm history 9
U16
RO
No
−
−
404Ah
00h
Alarm history 10
U16
RO
No
−
−
4064h
00h
Command speed [r/min]
INT32
RO
TxPDO
−
−
4067h
00h
Feedback speed [r/min]
INT32
RO
TxPDO
−
−
406Ah
00h
Direct I/O
U32
RO
TxPDO
−
−
406Bh
00h
Torque monitor [1=0.1 %]
INT16
RO
TxPDO
−
−
406Dh
00h
Cumulative load monitor
INT32
RO
TxPDO
−
−
407Bh
00h
Information
INT32
RO
TxPDO
−
−
407Ch
00h
Driver temperature [1=0.1 °C]
INT16
RO
TxPDO
−
−
407Dh
00h
Motor temperature [1=0.1 °C]
INT16
RO
TxPDO
−
−
407Eh
00h
Odometer [1=0.1 kRev]
INT32
RO
TxPDO
−
−
407Fh
00h
Tripmeter [1=0.1 kRev]
INT32
RO
TxPDO
−
−
4090h
00h
Feedback position 32-bit
counter
INT32
RO
TxPDO
−
−
4091h
00h
Command position 32-bit
counter
INT32
RO
TxPDO
−
−
4092h
00h
CST operating current [1=0.1 %]
INT16
RO
TxPDO
−
−
40A0h
00h
Main power supply count
INT32
RO
TxPDO
−
−
40A1h
00h
Main power supply time [min]
INT32
RO
TxPDO
−
−
40A2h
00h
Control power supply count *
INT32
RO
TxPDO
−
−
40A3h
00h
Inverter voltage [1=0.1 V]
INT16
RO
TxPDO
−
−
40A4h
00h
Main power supply voltage
[1=0.1 V]
INT16
RO
TxPDO
−
−
40A9h
00h
Elapsed time from BOOT [ms]
INT32
RO
TxPDO
−
−
40B7h
00h
Operation voltage mode
U8
RO
TxPDO
−
−
40B8h
00h
I/O status 1
U32
RO
TxPDO
−
−
40B9h
00h
I/O status 2
U32
RO
TxPDO
−
−
40BAh
00h
I/O status 3
U32
RO
TxPDO
−
−
40BBh
00h
I/O status 4
U32
RO
TxPDO
−
−
40BCh
00h
I/O status 5
U32
RO
TxPDO
−
−
40BDh
00h
I/O status 6
U32
RO
TxPDO
−
−
40BEh
00h
I/O status 7
U32
RO
TxPDO
−
−
40BFh
00h
I/O status 8
U32
RO
TxPDO
−
−
* It will be the number of times the main power supply is turned on if the control power supply is not connected.