Connection
28
2 Har
z
Connecting the motor cable
Use an Oriental Motor connection cable when extending the wiring distance between a motor and a driver. Refer to
p.32 for the model name.
z
Connecting the signal cable
Refer to “Prevention of noise propagation” on p.27.
z
Grounding method
•
Wires used to ground the motor must be as thick and short as possible so that no potential difference is generated
between the grounding points.
•
Choose a large, thick and uniformly conductive surface for the grounding point.
•
Make sure to ground the Protective Earth Terminal of the motor.
z
Example of installation and wiring
Host controller
Main power
supply
Control power
supply
Noise
filter
Noise
filter
AC
AC
Motor
Driver *1
Grounded panel
Power supply cable
(shielded cable)
Connection cable *2
Cable clamp
Cable
clamp
Cable
clamp
is a shield box.
is a ferrite core.
symbol indicate the grounding.
*1 The driver is grounded by making the heat sink contact directly with the grounded panel.
*2 An Oriental Motor cable is used.