![background image](http://html1.mh-extra.com/html/omron/cp1l-el20dr-d/cp1l-el20dr-d_operation-manual_743755042.webp)
8
Features and Main Functions
Section 1-1
Expansion Capability
for Serial Ports
Up to two Serial Communications Boards each with one RS-232C port or one
RS-422A/485 port can be added to a CPU Unit with 30 or 40 I/O points. One
Serial Communications Boards can be added to a CPU Unit with 20 I/O
points. With the serial communications port, it is easy to simultaneously con-
nect a computer, PT, PLC, and/or various components, such as an Inverter,
Temperature Controller, or Smart Sensor.
Note
(1) The Modbus-RTU easy master (available for all models) makes it easy to
control Modbus Slaves (such as Inverters) with serial communications.
After the Modbus Slave address, function, and data have been preset in
a fixed memory area (DM), messages can be sent or received indepen-
dently of the program by turning software switches.
MAC Address:
01234567890A
00
NC
02
04
06
08
10
00
02
04
06
08
10
01
COM
03
05
07
09
11
01
03
05
07
09
11
BKUP
ERR/ALM
LNK/ACT
SYSMAC
CP1L
POWER
RUN
INH
1
00
01
02
03
04
06
00
01
03
04
06
COM
02
COM
05
07
COM
COM(V+)
05
07
ANALOG INPUT
V1+ V2+ COM
2
NS-series PT, personal computer, bar code reader, etc.
CP1W-CIF01 RS-232C
Option Board
CP1W-CIF11/CIF12
RS-422A/485 Option Board
Inverter, etc. (See note 1.)
CP1L
CP1L-EM
RS-232C
RS-422A
CP1L-EM
MAC Address:
01234567890A
00
NC
02
04
06
08
10
00
02
04
06
08
10
01
COM
03
05
07
09
11
01
03
05
07
09
11
BKUP
ERR/ALM
LNK/ACT
SYSMAC
CP1L
POWER
RUN
INH
1
00
01
02
03
04
06
00
01
03
04
06
COM
02
COM
05
07
COM
COM(V+)
05
07
ANALOG INPUT
V1+ V2+ COM
2
MAC Address:
01234567890A
00
NC
02
04
06
08
10
00
02
04
06
08
10
01
COM
03
05
07
09
11
01
03
05
07
09
11
BKUP
ERR/ALM
LNK/ACT
SYSMAC
CP1L
POWER
RUN
INH
1
00
01
02
03
04
06
00
01
03
04
06
COM
02
COM
05
07
COM
COM(V+)
05
07
ANALOG INPUT
V1+ V2+ COM
2
Modbus-RTU
Inverter
Communications can be executed
independently of the program by setting
a Modbus-RTU command in the DM and
turning ON a software switch.
Содержание CP1L-EL20DR-D
Страница 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Страница 4: ...iv...
Страница 10: ...x...
Страница 22: ...xxii...
Страница 34: ...xxxiv Software Licenses and Copyrights 7...
Страница 178: ...144 Connecting the CX Programmer Section 5 1 Click the Connect button to connect and then connection online is completed...
Страница 192: ...158 Trial Operation and Debugging Section 5 3...
Страница 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Страница 666: ...632 Trouble Shooting Section 11 7...
Страница 696: ...662 Standard Models Appendix A...
Страница 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Страница 836: ...802 PLC Setup Appendix G...
Страница 838: ...804 TCP Status Transitions Appendix H...
Страница 840: ...806 Ethernet Network Parameters Appendix I...
Страница 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Страница 844: ...810 Ethernet Specifications Appendix K...
Страница 851: ...Index 817 work words 118 write protection 447...
Страница 852: ...818 Index...
Страница 854: ...820 Revision History...
Страница 855: ......