695
Auxiliary Area Allocations by Address
Appendix D
A26
04
Error Counter
Error Flag 0
This flag turns ON when an error
occurs in the error counter for
inverter positioning 0.
ON: Error
counter error
OFF: No error
---
Cleared
When
pulse out-
put to error
counter is
stopped
and abso-
lute value
of error
counter
present
value is
greater
than or
equal to
error
counter
error
detection
value
---
05
Error Counter
Pulse Output
Flag 0
This flag is ON while pulses are
being output to the output counter for
inverter positioning 0.
ON: Pulses
being output
OFF: Pulse
output
stopped
---
Cleared
When
pulse out-
put to error
counter 0
is started
---
06
Error Counter
Pulse Output
Acceleration/
Deceleration
Flag 0
This flag is ON while pulse output to
the output counter for inverter posi-
tioning 0 is accelerating or decelerat-
ing.
ON: Pulse
output to the
error counter
is accelerat-
ing or decel-
erating (i.e.,
the fre-
quency is
changing)
OFF: Pulse
output to the
error counter
is constant
---
Cleared
When
pulse out-
put fre-
quency to
error
counter is
changed
by ACC or
PLS2
instruction
---
07
Error Counter
Alarm Flag 0
This flag turns ON when an alarm
occurs in the error counter for
inverter positioning 0.
ON: Error
counter alarm
OFF: No error
counter alarm
---
Cleared
When
pulse out-
put to error
counter is
stopped
and abso-
lute value
of error
counter
present
value is
greater
than or
equal to
error
counter
alarm
detection
value
---
15
Inverter Posi-
tioning Output
Value Sign
Flag 0
This flag is ON when the inverter
positioning 0 output value is positive
and is OFF when it is negative.
ON: Positive
value
OFF: Nega-
tive value
---
Cleared
When
signed out-
put value is
between
0000 0000
and 7FFF
FFFF hex
---
A28
and
A29
---
Present Value
of Pulse Out-
put to Inverter
0, Relative
Value
These words contain the relative
value of the internal pulse output
when pulses are being output to the
error counter for inverter positioning
0.
Data range: 8000 0000 to 7FFF
FFFF hex (
−
2,147,483,648 to
2,147,483,647)
---
---
Cleared
Every error
counter 0
cycle
---
Address
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words
Bits
Содержание CP1L-EL20DR-D
Страница 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Страница 4: ...iv...
Страница 10: ...x...
Страница 22: ...xxii...
Страница 34: ...xxxiv Software Licenses and Copyrights 7...
Страница 178: ...144 Connecting the CX Programmer Section 5 1 Click the Connect button to connect and then connection online is completed...
Страница 192: ...158 Trial Operation and Debugging Section 5 3...
Страница 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Страница 666: ...632 Trouble Shooting Section 11 7...
Страница 696: ...662 Standard Models Appendix A...
Страница 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Страница 836: ...802 PLC Setup Appendix G...
Страница 838: ...804 TCP Status Transitions Appendix H...
Страница 840: ...806 Ethernet Network Parameters Appendix I...
Страница 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Страница 844: ...810 Ethernet Specifications Appendix K...
Страница 851: ...Index 817 work words 118 write protection 447...
Страница 852: ...818 Index...
Страница 854: ...820 Revision History...
Страница 855: ......