710
Auxiliary Area Allocations by Address
Appendix D
A310
All
Manufactur-
ing Lot Num-
ber, Lower
Digits
The manufacturing lot number is
stored in 6 digits hexadecimal. X, Y,
and Z in the lot number are con-
verted to 10, 11, and 12, respec-
tively.
Examples:
Lot number 01805
A310 = 0801, A311 = 0005
Lot number 30Y05
A310 =1130, A311 = 0005
---
Retained
Retained When the
power sup-
ply is
turned ON
---
A311
All
Manufactur-
ing Lot Num-
ber, Upper
Digits
A313
All
Error Informa-
tion
When a non-fatal error (Built-in
Ethernet error) occurs, the 4-digit
hexadecimal error information is writ-
ten to this word. When two or more
errors occur simultaneously, the
information of the highesterror code
will be recorded.
---
Cleared
Cleared
Refreshed
when error
occurs.
A315.10
A315.11
A315
10
Built-in Ether-
net Error Flag
ON when a Built-in Ethernet error
has occurred in memory.
---
Cleared
Cleared
Refreshed
when error
occurs.
A402.00,
A313
11
Logic Errors in
Setting Table
Flag
ON when an error occurs in routing
table, IP address table, or IP router
table.
---
Cleared
Cleared
Refreshed
when error
occurs.
A402.00,
A313
13
Option Board
Error Flag
ON when the Option Board is
removed while the power is being
supplied. CPU Unit operation will
continue and the ERR/ALM indicator
will flash.
OFF when the error has been
cleared.
---
Cleared
Cleared
Refreshed
when error
occurs.
A402.00,
A424
15
Flash Mem-
ory Error Flag
ON when writing to the internal flash
memory fails. CPU Unit operation
will continue and the ERR/ALM indi-
cator will flash.
OFF when the error has been
cleared.
---
Cleared
Cleared
Refreshed
when error
occurs.
A402.00
A316
to
A317
All
High-speed
Counter 2 PV
Contains the PV of high-speed
counter 2. A317 contains the left-
most 4 digits and A316 contains the
rightmost 4 digits.
The PV is cleared when operation
starts.
---
---
Cleared
Refreshed
each cycle
during
oversee
process.
Refreshed
when
PRV(881)
instruction
is exe-
cuted.
---
A318
to
A319
All
High-speed
Counter 3 PV
Contains the PV of high-speed
counter 3. A319 contains the left-
most 4 digits and A318 contains the
rightmost 4 digits.
The PV is cleared when operation
starts.
---
---
Cleared
---
A320
00
High-speed
Counter 2
Range 1 Com-
parison Condi-
tion Met Flag
These flags indicate whether the PV
is within the specified ranges when
high-speed counter 2 is being oper-
ated in range-comparison mode.
Cleared at beginning of operation.
Cleared when range comparison
table is registered.
OFF: PV not in range
ON: PV in range
---
---
Cleared
Refreshed
each cycle
during
oversee
process.
Refreshed
when
PRV(881)
instruction
is exe-
cuted.
---
Address
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words
Bits
Содержание CP1L-EL20DR-D
Страница 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Страница 4: ...iv...
Страница 10: ...x...
Страница 22: ...xxii...
Страница 34: ...xxxiv Software Licenses and Copyrights 7...
Страница 178: ...144 Connecting the CX Programmer Section 5 1 Click the Connect button to connect and then connection online is completed...
Страница 192: ...158 Trial Operation and Debugging Section 5 3...
Страница 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Страница 666: ...632 Trouble Shooting Section 11 7...
Страница 696: ...662 Standard Models Appendix A...
Страница 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Страница 836: ...802 PLC Setup Appendix G...
Страница 838: ...804 TCP Status Transitions Appendix H...
Страница 840: ...806 Ethernet Network Parameters Appendix I...
Страница 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Страница 844: ...810 Ethernet Specifications Appendix K...
Страница 851: ...Index 817 work words 118 write protection 447...
Страница 852: ...818 Index...
Страница 854: ...820 Revision History...
Страница 855: ......