252
Pulse Outputs
Section 7-2
Operations Affecting the Origin Status (Established/Not Established Status)
The following table shows the operations that can affect the origin status (ori-
gin established or no-origin), such as changing the operating mode and exe-
cuting certain instructions.
The No-origin Flag will be ON when the corresponding pulse output's origin is
not established and OFF when the origin is established.
Absolute pulse
specification
The absolute pulse specification cannot be
used when the origin location is undetermined,
i.e., when the system is operating in the relative
coordinate system. An instruction execution
error will occur.
Positions the system to an absolute position rel-
ative to the origin.
The number of movement pulses and move-
ment direction are calculated automatically from
the current position (pulse output PV) and target
position.
The following example shows the number of
pulses setting = +100.
Number of movement pulses = Number of
pulses setting - Pulse output PV when instruc-
tion is executed
The movement direction is determined automat-
ically.
Pulse output PV when instruction is executed =
Number of pulses setting
Pulse output PV range:
8000 0000 to 7FFF FFFF hex
Number of pulses setting range:
8000 0000 to 7FFF FFFF hex
Pulse output
specified in
PULS(886) or
PLS2(887)
Coordinate system
Relative coordinate system
Absolute coordinate system
Origin not established:
The No-origin Flag will be ON in this case.
Origin established:
The No-origin Flag will be OFF in this case.
+100
+200
0
Number of pulses
setting
II
Number of
movement pulses
Target
position =
number of
pulses
setting
Current
position
Pulse
output PV
Origin
Current status
PROGRAM mode
RUN mode or MONITOR
mode
Operation
Origin
established
Origin not
established
Origin
established
Origin not
established
Operat-
ing mode
change
Switch to
RUN or
MONITOR
Status
changes to
“Origin not
established.”
“Origin not
established”
status contin-
ues.
---
---
Switch to
PROGRAM
---
---
“Origin
established”
status contin-
ues.
“Origin not
established”
status contin-
ues.
Содержание CP1L-EL20DR-D
Страница 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Страница 4: ...iv...
Страница 10: ...x...
Страница 22: ...xxii...
Страница 34: ...xxxiv Software Licenses and Copyrights 7...
Страница 178: ...144 Connecting the CX Programmer Section 5 1 Click the Connect button to connect and then connection online is completed...
Страница 192: ...158 Trial Operation and Debugging Section 5 3...
Страница 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Страница 666: ...632 Trouble Shooting Section 11 7...
Страница 696: ...662 Standard Models Appendix A...
Страница 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Страница 836: ...802 PLC Setup Appendix G...
Страница 838: ...804 TCP Status Transitions Appendix H...
Страница 840: ...806 Ethernet Network Parameters Appendix I...
Страница 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Страница 844: ...810 Ethernet Specifications Appendix K...
Страница 851: ...Index 817 work words 118 write protection 447...
Страница 852: ...818 Index...
Страница 854: ...820 Revision History...
Страница 855: ......