320
Inverter Positioning
Section 7-3
■
Precaution for Inverter Settings
• Set the stop time to 0 second.
• Use Modus-RTU communication when the send delay setting is above
10ms.
However, if the send delay time is too long, the inverter response to the
command from the PLC will be slow.
7-3-3
Functional Overview
Operation
1.
To use inverter positioning, the motor and encoder specifications, feed-
back gain, and other parameters must be set in the PLC Setup. The high-
speed counter and inverter must also be set.
2.
Pulse output instructions, such as PLS2 or PULS with SPED, are used to
execute positioning. Although normally the pulse output instructions are
used to output pulses from CP1L-EL/EM output contacts, when inverter
positioning 0 or inverter positioning 1 is enabled in the PLC Setup, the in-
ternal position error counter (called simply the “error counter”) is enabled
and the pulse output instruction will output internal pulses to the error
counter. Both error counters 0 and 1 can be used at the same time.
3.
For the number of pulses (i.e., the amount of movement) set in the pulse
output instruction, use the number of feedback pulses from the encoder.
For the pulse frequency set in the pulse output instruction, use the motor
power supply frequency converted to the feedback pulse frequency from
the encoder. (Refer to 7-3-7 Determining the Internal Pulse Output Fre-
quency for details.)
4.
Specify an inverter positioning port for the pulse output instruction (port 0:
0020, port 1: 0021). The internal pulses will be output to the error counter
for the specified port.
CP1L-EL/EM
Feedback pulses
(See note.)
CP1W-CIF11/CIF12
CP1W-DA021/DA041
CP1W-MAD11
Point 1.
Point 2.
Point 3.
Point 4.
Point 8.
Point 9.
Point 7.
Point 5.
Point 6.
Point 1.
PLC Setup
■
Inverter Positioning
Settings
⋅
Enable function
⋅
Calculation cycle
⋅
Motor/encoder specs
⋅
Gain
⋅
In-position width
⋅
Min./max. output
⋅
Error settings
⋅
Etc.
■
High-speed
Counter Settings
⋅
Enable counter
⋅
Mode settings
⋅
Etc.
■
Serial Port Settings
(When using serial
communications for
outputs to the inverter.)
Ladder Program
Port Setting
No. 0: #0020
No. 1: #0021
Frequency command
conversions for inverter
MOV
(automatically
calculated inverter
frequency
commands
MOV
(forward/reverse
operation)
Output to CP1W-CIF11/
CIF12
Analog output
settings
Output to Analog Unit
Analog output: Output bits
Serial: Serial communications
Forward/reverse commands
and other commands
Error Counter Status
(forward/reverse commands, in-position
status, etc.)
Stored in Auxiliary Area bits.
Position
feedback
Internal pulses
Error
counter
Conversion
using PLC Setup
Gain
Auxiliary
Area word
0.01 Hz
increments
Serial or
analog
output
Inverter
Power
supply
frequency
Inductive
motor
Encoder
High-speed
counter input
terminal
Output
compensation
(upper/lower
limits)
Pulse output
instruction
(PLS2, PULS +
SPED, etc.)
MOV
(operation
commands,
output values,
present values
Positioning
instructions
Modbus
communications
register settings
Note: There is no speed or current (i.e.,
torque) loop.
Содержание CP1L-EL20DR-D
Страница 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Страница 4: ...iv...
Страница 10: ...x...
Страница 22: ...xxii...
Страница 34: ...xxxiv Software Licenses and Copyrights 7...
Страница 178: ...144 Connecting the CX Programmer Section 5 1 Click the Connect button to connect and then connection online is completed...
Страница 192: ...158 Trial Operation and Debugging Section 5 3...
Страница 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Страница 666: ...632 Trouble Shooting Section 11 7...
Страница 696: ...662 Standard Models Appendix A...
Страница 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Страница 836: ...802 PLC Setup Appendix G...
Страница 838: ...804 TCP Status Transitions Appendix H...
Страница 840: ...806 Ethernet Network Parameters Appendix I...
Страница 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Страница 844: ...810 Ethernet Specifications Appendix K...
Страница 851: ...Index 817 work words 118 write protection 447...
Страница 852: ...818 Index...
Страница 854: ...820 Revision History...
Страница 855: ......