121
Timers and Counters
Section 4-9
4-9
Timers and Counters
4-9-1
Timer Area (T)
The 4,096 timer numbers (T0000 to T4095) are shared by the TIM,
TIMX(550), TIMH(015), TIMHX(551), TMHH(540), TIMHHX(552), TTIM(087),
TTIMX(555), TIMW(813), TIMWX(816), TMHW(815), and TIMHWX(817)
instructions. Timer Completion Flags and present values (PVs) for these
instructions are accessed with the timer numbers.
The TIML(542), TIMLX(553), MTIM(543), and MTIMX(554) instructions do not
use timer numbers.
When a timer number is used in an operand that requires bit data, the timer
number accesses the Completion Flag of the timer. When a timer number is
used in an operand that requires word data, the timer number accesses the
PV of the timer. Timer Completion Flags can be used as often as necessary
as normally open and normally closed conditions and the values of timer PVs
can be read as normal word data.
The refresh method for timer PVs can be set from the CX-Programmer to
either BCD or binary.
Note
It is not recommended to use the same timer number in two timer instructions
because the timers will not operate correctly if they are timing simultaneously.
(If two or more timer instructions use the same timer number, an error will be
generated during the program check, but the timers will operate as long as the
instructions are not executed in the same cycle.)
The following table shows when timers will be reset or maintained.
Note
1.
If the IOM Hold Bit (A500.12) is ON, the PV and Completion Flag will be
retained when a fatal error occurs (including execution of FALS instruc-
tions) or the operating mode is changed from PROGRAM mode to RUN or
MONITOR mode or vice-versa. The PV and Completion Flag will be
cleared when power is cycled.
2.
If the IOM Hold Bit (A50012) is ON and the PLC Setup’s IOM Hold Bit Sta-
tus at Startup setting is set to protect the IOM Hold Bit, the PV and Com-
pletion Flag will be retained when the PLC’s power is cycled.
3.
Since the TIML(542), TIMLX(553), MTIM(543), and MTIMX(554) instruc-
tions do not use timer numbers, they are reset under different conditions.
Refer to the descriptions of these instructions for details.
Instruction name
Effect on PV and Completion Flag
Operation in
Jumps and Interlocks
Mode change
1
PLC start-up
2
CNR(545)/CN
RX(547)
Jumps
(JMP-JME) or
Tasks on
standby
4
Interlocks
(IL-ILC)
TIMER: TIM/TIMX(550)
PV
→
0
Flag
→
OFF
PV
→
0
Flag
→
OFF
PV
→
9999
Flag
→
OFF
PVs refreshed in
operating timers
PV
→
SV
(Reset to SV.)
Flag
→
OFF
HIGH-SPEED TIMER:
TIMH(015)/TIMHX(551)
ONE-MS TIMER:
TMHH(540)/TMHHX(552)
ACCUMULATIVE TIMER:
TTIM(087)/TTIMX(555)
PV Maintained
PV Maintained
TIMER WAIT:
TIMW(813)TIMWX(816)
PVs refreshed in
operating timers
---
HIGH-SPEED TIMER WAIT:
TMHW(815)/TMHWX(817)
---
Содержание CP1L-EL20DR-D
Страница 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Страница 4: ...iv...
Страница 10: ...x...
Страница 22: ...xxii...
Страница 34: ...xxxiv Software Licenses and Copyrights 7...
Страница 178: ...144 Connecting the CX Programmer Section 5 1 Click the Connect button to connect and then connection online is completed...
Страница 192: ...158 Trial Operation and Debugging Section 5 3...
Страница 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Страница 666: ...632 Trouble Shooting Section 11 7...
Страница 696: ...662 Standard Models Appendix A...
Страница 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Страница 836: ...802 PLC Setup Appendix G...
Страница 838: ...804 TCP Status Transitions Appendix H...
Страница 840: ...806 Ethernet Network Parameters Appendix I...
Страница 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Страница 844: ...810 Ethernet Specifications Appendix K...
Страница 851: ...Index 817 work words 118 write protection 447...
Страница 852: ...818 Index...
Страница 854: ...820 Revision History...
Страница 855: ......