Inverter Positioning
Section 7-3
• MODE CONTROL (INI)
Port: Inverter positioning, stopping inverter positioning
• HIGH-SPEED COUNTER PV READ (PRV)
Port: Inverter positioning, Operation: Reading error counter, inverter posi-
tioning status, or error counter present value
■
Automatic Calculation of Inverter Frequency Commands
• For either serial communications or an analog output, the power supply
frequency per motor revolutions/s, the number of encoder pulses per
motor revolution, and the error counter calculation cycle can be set in the
PLC Setup to automatically calculate the inverter frequency command
values and store it in A23/A33 in increments of 0.01 Hz.
• For serial communications, the ladder program is used to output the value
in A23/A33 to the inverter using serial communications.
• For analog output, the value in A23/A33 can be scaled to analog output
values and output from the Analog Unit to the inverter.
■
Forward/Reverse Operation Commands, Stopping Commands, Etc.
• The Forward Command Flag (A26.01/A36.01) and Reverse Command
Flag (A26.02/A36.02) can be used as input conditions for forward and
reverse operation commands.
• The Operation Command Flag (A26.00/A36.00) and In-position Flag
(A26.03/A36.03) can be used as input conditions to execute scaling to
inverter frequency commands and to execute stop commands.
7-3-6
Instruction Specifications
The normal pulse output instructions are used (PLS2, PULS + SPED, or
PULS + ACC). One of the inverter positioning ports is specified as the port for
the instruction. Just like pulses are output externally for the normal pulse out-
put instructions, error counter pulses are accumulated in the internal error
counter when executing inverter positioning.
Port Designation
Operand
Specifications
When executing pulse output instructions or status read instructions for
inverter positioning, a port number for inverter positioning is specified for the
port operand of the instruction. The following values are used.
0020 hex: Inverter positioning 0
0021 hex: Inverter positioning 1
When reading the present value of inverter positioning, use the following val-
ues to specified the port number for inverter positioning.
0030 hex: Inverter positioning 0 (signed)
0031 hex: Inverter positioning 1 (signed)
Set value
Specified port
Applicable instructions
0000
Pulse output 0
---
0001
Pulse output 1
---
0002
Pulse output 2
---
0003
Pulse output 3
---
0010
High-speed counter input 0
---
0011
High-speed counter input 1
---
0012
High-speed counter input 2
---
0013
High-speed counter input 3
---
0020
Inverter positioning 0
SPED, PULS, ACC, PLS2, INI, PRV, ORG
0021
Inverter positioning 1
SPED, PULS, ACC, PLS2, INI, PRV, ORG
Содержание CP1L-EL20DR-D
Страница 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Страница 4: ...iv...
Страница 10: ...x...
Страница 22: ...xxii...
Страница 34: ...xxxiv Software Licenses and Copyrights 7...
Страница 178: ...144 Connecting the CX Programmer Section 5 1 Click the Connect button to connect and then connection online is completed...
Страница 192: ...158 Trial Operation and Debugging Section 5 3...
Страница 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Страница 666: ...632 Trouble Shooting Section 11 7...
Страница 696: ...662 Standard Models Appendix A...
Страница 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Страница 836: ...802 PLC Setup Appendix G...
Страница 838: ...804 TCP Status Transitions Appendix H...
Страница 840: ...806 Ethernet Network Parameters Appendix I...
Страница 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Страница 844: ...810 Ethernet Specifications Appendix K...
Страница 851: ...Index 817 work words 118 write protection 447...
Страница 852: ...818 Index...
Страница 854: ...820 Revision History...
Страница 855: ......