MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-612
STEP 6. Check the backup power supply voltage at ECM
harness side connector C-58 <M/T> or PCM harness side
connector C-55 <A/T>.
(1) Disconnect the connector C-58 <M/T> or C-55 <A/T> and
measure at the harness side.
(2) Measure the voltage between terminal 60 <M/T> or 66 <A/
T> and ground.
•
Voltage should be battery positive voltage.
Q: Is the voltage normal?
YES :
Go to Step 7.
NO :
Check harness connector C-07 at intermediate
connector for damage, and repair or replace as
required. Refer to, GROUP 00E, Harness Connector
Inspection
. If intermediate connectors are in
good condition, repair harness wire between fusible
link (3) and ECM connector C-58 terminal 60 <M/T>
or PCM connector C-55 terminal 66 <A/T> because of
open circuit. Then confirm that the malfunction
symptom is eliminated.
STEP 7. Check the continuity at ECM harness side
connector C-58 <M/T> or PCM harness side connector C-
55 <A/T>.
(1) Disconnect the connector C-58 <M/T> or C-55 <A/T> and
measure at the harness side.
(2) Check for the continuity between terminal (46, 58) <M/T> or
(42, 48) <A/T> and ground.
•
Should be less than 2 ohm.
Q: Is the continuity normal?
YES :
Go to Step 8.
NO :
Repair harness wire between ECM connector C-58
terminal (46, 58) <M/T> or PCM connector C-55
terminal (42, 48) <A/T> and ground because of open
circuit or harness damage. Then confirm that the
malfunction symptom is eliminated.
AK000374AC
47 46 45
41
42
43
44
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
<M/T>
C-58 HARNESS
SIDE CONNECTOR
AK000375AC
<A/T>
C-55 HARNESS
SIDE CONNECTOR
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
AK000376
AC
47 46 45
41
42
43
44
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
<M/T>
C-58 HARNESS
SIDE CONNECTOR
AKX01437
<A/T>
C-55 HARNESS
SIDE CONNECTOR
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
AH